CALCULATION OF COOLING LOAD IN COLD STORAGE FOR CATCH STORAGE

Mula Tumpu, Moh. Nurhabibie Eka Putra, Juniawan Preston Siahaan, M. Zaky Latief Abrori, Bobby Demeianto, Dendi Haris

Abstract


This study aims to calculate the cooling load required in Cold Storage to store fish catches. Cold Storage is an important facility in the fisheries industry to maintain the quality and freshness of the product. Accurate cooling load calculation is essential to design an efficient and energy-saving refrigeration system. The methodology used includes data collection on Cold Storage specifications, environmental conditions, and characteristics of the stored products. The cooling load is calculated by considering factors such as transmission loads through walls, roofs, and floors; product loads; air infiltration loads; internal loads from lights, equipment, and personnel; and other loads. The calculation results show that the total cooling load for Cold Storage with a certain capacity is 17.68 kW. Sensitivity analysis was conducted to evaluate the effect of various parameters on the cooling load. This study also provides recommendations for optimizing Cold Storage design and operational strategies to improve energy efficiency. The results of this study can be used as a reference in designing and operating Cold Storage for more effective and economical storage of fish catches.

Keywords


Coefficient of performance (COP), cold storage, the refrigeration system.

Full Text:

PDF

References


Djafar, Z., & Piarah, W. H. (2017). ANALISA KINERJA MESIN REFRIGERASI RUMAH TANGGA DENGAN VARIASI REFRIGERANT. Jurnal Teknologi Terapan |, 3(2).

Fajarani, R. M., Handoyo, Y., & Rahmanto, R. H. (2019). ANALISIS BEBAN PENDINGINAN PADA COLD STORAGE UNTUK PENYIMPANAN DAGING. In Jurnal Ilmiah Teknik Mesin (Vol. 7, Issue 1). http://ejournal.unismabekasi.ac.id

Planning of Air Conditioner Cooling Load In The Dean Room Of The Faculty Of Engineering and Information Technology University Of PGRI Semarang. (2022). Journal of Materials Exploration and Findings, 1(1). https://doi.org/10.7454/jmef.v1i1.1000

Rodriguez-Martinez, V., Velazquez, G., Massa-Barrera, S., Welti-Chanes, J., Fagotti, F., & Torres, J. A. (2019). Estimation of Safety and Quality Losses of Foods Stored in Residential Refrigerators. Food Engineering Reviews, 11(3), 184–199. https://doi.org/10.1007/s12393-019-09192-1

Siagian, S., Studi, P., Mesin, T., Jakarta, V., & Selatan, J. (2017). PERHITUNGAN BEBAN PENDINGIN PADA COLD STORAGE UNTUK PENYIMPANAN IKAN TUNA PADA PT.X (Vol. 13, Issue 1).




DOI: http://dx.doi.org/10.15578/aj.v6i2.14671

Refbacks

  • There are currently no refbacks.




Public Services

 


Citation

           

Pusat Penelitian dan Pengabdian Kepada Masyarakat
Politeknik Kelautan dan Perikanan Dumai

Jl. Wan Amir No. 1, Kel. Pangkalan Sesai, Kec. Dumai Barat, Kota Dumai

Telp/Fax: (0765) 4300443

Creative Commons License

This work is licensed under a Creative Commons Attribution-ShareAlike 4.0 International License.

View My Stats